RFC install disabled refuge alarm systems for commercial premises across Dublin and Leinster. Legally required in multi-storey buildings. BS 5839 and IS 3217 compliant. Free site survey. Same day compliance certificate.

Legal
Requirement
BS5839
Compliant
Free
Site Survey
SameDay
Certificate
Disabled Refuge Systems
⚖️
Legally Required
📋
BS 5839 Compliant
📜
Same Day Certificate
🇮🇪
100% Irish Owned

Disabled Refuge Alarm
Systems — BS 5839

A disabled refuge system provides a two-way voice communication link between a refuge point — a protected area where a person with mobility difficulties can wait safely during evacuation — and the building's fire control point or reception. RFC install BS 5839 compliant disabled refuge systems for commercial premises across Dublin and Leinster.

🔔
Alarm Activates

Fire alarm activates. Person with mobility difficulties proceeds to the nearest refuge point and presses the call button.

🎙
Two-Way Comms

Refuge unit establishes two-way voice communication with the fire control panel at reception or the designated control point.

Rescue Dispatched

Fire warden or emergency services are alerted to the exact location of the person waiting at the refuge point for evacuation assistance.

Why Choose RFC
  • BS 5839 Part 9 compliant installation
  • Free site survey — no obligation
  • Same day compliance certificate
  • Integrated with fire alarm system
  • Annual service contract available
  • Hotels, offices, schools, care homes
  • New builds and fit-out installations
  • Replacement of existing systems
  • Combined with fire & security contract
  • 100% Irish owned — Est. 2005
Get a Free Site Survey 📞 (01) 8395116

Where Are Disabled Refuge Systems Required?

Under Irish Building Regulations Part M and BS 5839 Part 9, disabled refuge systems are required in:

  • All multi-storey commercial buildings with more than one floor above or below ground level
  • Hotels — stairwells and lift lobbies on all floors
  • Office buildings — all floors above ground floor
  • Schools — multi-storey buildings
  • Hospitals and care homes — all areas accessible to residents and patients
  • Shopping centres and retail premises — upper floors
  • Any building to which the public has access with more than one floor

What a Disabled Refuge System Includes

  • Refuge call points at all designated refuge areas — typically stairwell landing areas
  • Master control unit at the fire control point or reception
  • Two-way voice communication between refuge points and control unit
  • Visual indicators at refuge points and control unit
  • Battery backup — system remains operational during power failure
  • Integration with building fire alarm system
  • BS 5839 Part 9 compliant signage at all refuge points

Annual Testing & Servicing

Under BS 5839 Part 9, disabled refuge systems must be tested and serviced annually by a competent person. RFC carry out annual testing and servicing for all disabled refuge systems and issue a compliance certificate on the same day. Monthly functional testing is also recommended and can be carried out by a nominated person on your premises following RFC's handover training.

Sectors We Cover

  • Hotels — all floors above ground level, stairwell refuge points
  • Offices — multi-storey office buildings across Dublin
  • Schools — multi-storey school buildings
  • Care homes — full building coverage, HIQA compliant
  • Retail — shopping centres and multi-level retail premises